IRIS 6 X-RAY
|
|
Pipeline diameter range
|
:
|
6 to 18’
|
|
Length without the X-ray head
|
:
|
695 mm
|
|
Speed moving
|
:
|
13m/mn
|
|
Accepted climbing
|
:
|
30% - 16,6°
|
|
Maximum bend
|
:
|
10d
|
|
Operating temperature
|
:
|
40° to +80°C
|
|
Motor propulsion
|
:
|
2
|
|
Propulsion battery power
|
:
|
24V Ni/Cad
|
|
Propulsion battery capacity
|
:
|
4 Ah
|
|
X-ray battery power
|
:
|
48V Ni/Cad
|
|
X-ray battery capacity
|
:
|
7 Ah
|
|
Propulsion wheels
|
:
|
Clinging rubber
|
|
X-ray wheels
|
:
|
Orthogonal
|
|
Distance autonomy (propulsion)
|
:
|
3km
|
|
Exposure autonomy (X-ray)
|
:
|
50’
According exposure time
|
|
Positioning accuracy (accepted climbing included)
|
:
|
+/- 5 mm
|
|
Adjustable exposure
|
:
|
0 à 999 s
|
|
Safety exposure delay
|
:
|
10s
|
|
Pilot Command Caesium 137
|
:
|
740MBq 20mCi
|
|
Pilot Command Cobalt 60
|
:
|
370MBq 10mCi
|
|
Pilot Command magnetic
|
:
|
Magnetic System
|
|
|
|
Panoramic X-Ray Generator
|
|
|
|
Output rating kV
|
:
|
180
|
|
Tube current mA
|
:
|
2
|
|
Focal spot size
|
:
|
4 x 0.5 mm
|
|
Working ambient temperature
|
:
|
-25°C to 70°C
|
|
Dimensions
|
:
|
120 x 590mm
|
|
Weight
|
:
|
9.5kg
|